VS 83 B

VS 80 A
-
VS 83 B
Downstream
Inputs 4 pcs. Frequency range input 1 40...108 MHz (FS Band 1 and FM) Frequency range input 2 160...260 MHz (FS Band 2) Frequency range input 3 470...862 MHz (FS Band 4 and 5) Frequency range input 4 470...862 MHz (FS Band 4 and 5) Gain input 1 20 dB (input level regulator 0-20 dB) Gain input 2 20 dB (input level regulator 0-20 dB) Gain input 3 30 dB (input level regulator 0-16 dB) Gain input 4 30 dB (input level regulator 0-16 dB) Output level 1 106 dBµV Output level 2 106 dBµV Connectors
F-socket 6 pcs. General data
Operating voltage AC 230 V Feeding voltage DC 24 V DC (50mA) Power consumption 7 W Screening factor (EMC) Class A, EN 50083-2 Operating temperature range -10...+65 °C Protection class IP20 -
VS 80 A
- Screening class A
- F-socket, 75Ohm
Downstream
Inputs 4 pcs. Frequency range input 1 47...108 MHz (FS Band 1 and FM) Frequency range input 2 174...230 MHz (FS Band 2) Frequency range input 3 470...862 MHz (FS Band 4) Frequency range input 4 470...862 MHz (FS Band 5) Gain input 1 36 dB (input level regulator 0-18 dB) Gain input 2 37 dB (input level regulator 0-18 dB) Gain input 3 42 dB (input level regulator 0-18 dB) Gain input 4 42 dB (input level regulator 0-18 dB) Output level 1 119 dBµV (EN50083-5) Output test point -20 dB Connectors
F-socket 6 pcs. General data
Operating voltage AC 230 V Power consumption 3.5 W Screening factor (EMC) Class A, EN 50083-2 Operating temperature range -20...+55 °C