VX 82 2P
- Zinc die-cast housing
- Flap-lid for easy handling
- Screening ensured with open flap-lid
- Configuration of attenuators and equalizers via PADs and jumpers
- Measuring point at the output
- Return path amplifier on the circuit board
- Low power consumption, high output level
- Unitymedia certfied
Downstream |
|
Inputs | 1 pcs. |
Frequency range downstream | 85...1006 MHz |
Gain downstream | 33 dB |
Noise figure downstream | ≤6,0 dB |
attenuator downstream | 0...20 dB |
equaliser downstream | 0...20 dB (Interstage-equalizer 0/7 dB) |
Output level 1 | 99 dBµV (CENELEC 42 channels, flat, at CSO/CTB >60 dB/>60 dB) |
Upstream |
|
Frequency range upstream | 5...65 MHz |
Gain upstream | 23 dB |
noise figure upstream | ≤5 dB |
attenuator upstream input | 0...20 dB |
Equalizer US | 3 dB (Interstage, fix) |
Output level 4 | 120 dBµV (KDG 1TS140 - average load with QAM 64 MER >35 dB, BER 1x10-8) |
Output test point | -20 dB |
Connectors |
|
F-socket | 3 pcs. |
General data |
|
Operating voltage AC | 230 V (50/60 Hz) |
Power consumption | ≤6,0 W |
EMC | EN 50083-2 |
Dimensions (width x height x depth) | 163x90x50 mm |
Operating temperature range | -20...+55 °C |
Protection class | IP20 |
Lightning protection | 1 kV (EN60728-3, 1,2/50 µs pulse) |
-
Parameters
-