VX 87
VX 86
VX 83 0S
VX 82 2P
VX 82 0S
VX 82
VX 81 0S
-
VX 87
- With passive return path
- Adjustable level and equalizer
- F-connectors
- Wall mounting
- Metal housing
Downstream
Inputs 1 pcs. Frequency range downstream 47...862 MHz Gain downstream 28...31 dB Noise figure downstream <8 dB attenuator downstream 0...18 dB equaliser downstream 3...18 dB interstage equalizer downstream 3 dB (constant) Output level 1 96 dBµV (DS, CENELEC 42 channels, flat) Output level 2 98.5 dBµV (DS, CENELEC 42 channels, 6 dB slope) Output level 3 114 dBµV (DS, EN50083-5, 3.Ord.) Upstream
Frequency range upstream 5...30 MHz (passive) Connectors
F-socket 2 pcs. General data
Operating voltage AC 230 V (50/60 Hz) Power consumption 3.5 W EMC Class A, EN 50083-2 Dimensions (width x height x depth) 163x90x47 mm Operating temperature range -20...+55 °C Protection class IP20 Lightning protection 1 kV (EN61000-4-5, 1,2/50 µs pulse) -
VX 86
- With passive return path
- Adjustable level and equalizer
- F-connectors
- Wall mounting
- Metal housing
Downstream
Inputs 1 pcs. Frequency range downstream 47...862 MHz Gain downstream 18...21 dB Noise figure downstream <8 dB attenuator downstream 0...18 dB equaliser downstream 3...18 dB interstage equalizer downstream 3 dB (constant) Output level 1 96 dBµV (DS, CENELEC 42 channels, flat) Output level 2 98.5 dBµV (DS, CENELEC 42 channels, 6 dB slope) Output level 3 114 dBµV (DS, EN50083-5, 3.Ord.) Upstream
Frequency range upstream 5...30 MHz (passive) Connectors
F-socket 2 pcs. General data
Operating voltage AC 230 V (50/60 Hz) Power consumption 3.5 W EMC Class A, EN 50083-2 Dimensions (width x height x depth) 163x90x47 mm Operating temperature range -20...+55 °C Protection class IP20 Lightning protection 1 kV (EN61000-4-5, 1,2/50 µs pulse) -
VX 83 0S
- Compact housing MiniLine
- All RF connections F-connector
- setting elements with rotary switch
- Flap-lid for easy handling
Down-Stream / DS
Frequency range downstream 85...1006 MHz Gain downstream 31 dB Frequency response ≤ ± 0,8 dB Output level ≥ 102 dBµV (CENELEC 42 Ch, flat, CTB/CSO ≥ 60 dB) IN-ATT (adjuster) 0...20 dB IN-EQ (adjuster) 0...20 dB Interstage-EQ (fix) 3 dB noise figure ≤ 6,5 dB Upstream (US)
US frequency range 5...65 MHz Gain upstream 25 dB Frequency response upstream ≤ ± 0,8 dB Output level 120 dBµV (KDG TS140 medium load; BER <1e 10-6) IN-ATT (adjuster) 0...20 dB noise figure ≤ 4,5 dB General data
HF-connections F Impedance 75 Ω Return loss ≥ 14 dB (> 40 MHz - 1,5 dB Oktave ≥ 10 dB) Lightning protection 1 kV (severity 1 / EN60728-3) EMC EN50083-2 Supply voltage 230 V (± 10%) Power consumption ≤ 5,5 W Ambient temperature -20...+55 °C Storage temperature -25...+75 °C Protection class IP20 -
VX 82 2P
- Zinc die-cast housing
- Flap-lid for easy handling
- Screening ensured with open flap-lid
- Configuration of attenuators and equalizers via PADs and jumpers
- Measuring point at the output
- Return path amplifier on the circuit board
- Low power consumption, high output level
- Unitymedia certfied
Downstream
Inputs 1 pcs. Frequency range downstream 85...1006 MHz Gain downstream 33 dB Noise figure downstream ≤6,0 dB attenuator downstream 0...20 dB equaliser downstream 0...20 dB (Interstage-equalizer 0/7 dB) Output level 1 99 dBµV (CENELEC 42 channels, flat, at CSO/CTB >60 dB/>60 dB) Upstream
Frequency range upstream 5...65 MHz Gain upstream 23 dB noise figure upstream ≤5 dB attenuator upstream input 0...20 dB Equalizer US 3 dB (Interstage, fix) Output level 4 120 dBµV (KDG 1TS140 - average load with QAM 64 MER >35 dB, BER 1x10-8) Output test point -20 dB Connectors
F-socket 3 pcs. General data
Operating voltage AC 230 V (50/60 Hz) Power consumption ≤6,0 W EMC EN 50083-2 Dimensions (width x height x depth) 163x90x50 mm Operating temperature range -20...+55 °C Protection class IP20 Lightning protection 1 kV (EN60728-3, 1,2/50 µs pulse) -
VX 82 0S
- Compact housing MiniLine
- All RF connections F-connector
- setting elements with rotary switch
- Flap-lid for easy handling
Down-Stream / DS
Frequency range downstream 85...1006 MHz Gain downstream 31 dB Frequency response ≤ ± 0,8 dB Output level ≥ 98 dBµV (CENELEC 42 Ch, flat, CTB/CSO ≥ 60 dB) IN-ATT (adjuster) 0...20 dB IN-EQ (adjuster) 0...20 dB Interstage-EQ (fix) 3 dB noise figure ≤ 6,5 dB Upstream (US)
US frequency range 5...65 MHz Gain upstream 25 dB Frequency response upstream ≤ ± 0,8 dB Output level 120 dBµV (KDG TS140 medium load; BER <1e 10-6) IN-ATT (adjuster) 0...20 dB noise figure ≤ 4,5 dB General data
HF-connections F Impedance 75 Ω Return loss ≥ 14 dB (> 40 MHz - 1,5 dB Oktave ≥ 10 dB) Lightning protection 1 kV (severity 1 / EN60728-3) EMC EN50083-2 Supply voltage 230 V (± 10%) Power consumption ≤ 5,5 W Ambient temperature -20...+55 °C Storage temperature -25...+75 °C Protection class IP20 -
VX 82
- With active return path
- Adjustable level and equalizer
- F-connectors
- Wall mounting
- Metal housing
Downstream
Inputs 1 pcs. Frequency range downstream 87...862 MHz Gain downstream 28...31 dB Noise figure downstream <8 dB attenuator downstream 0...18 dB equaliser downstream 3...18 dB interstage equalizer downstream 3 dB Output level 1 96 dBµV (DS, CENELEC 42 channels, flat) Output level 2 98.5 dBµV (DS, CENELEC 42 channels, 6 dB slope) Output level 3 114 dBµV (DS, EN50083-5, 3.Ord) Upstream
Frequency range upstream 5...65 MHz Gain upstream 28 dB noise figure upstream 6.5 dB attenuator upstream input 0...12 dB attenuator upstream output 10 dB (Jumper) Output level 4 112 dBµV (EN50083-5, 3.Ord.) Connectors
F-socket 2 pcs. General data
Operating voltage AC 230 V (50/60 Hz) Power consumption 3.5 W EMC EN 50083-2 Dimensions (width x height x depth) 163x90x47 mm Operating temperature range -20...+55 °C Protection class IP20 Lightning protection 1 kV (EN61000-4-5, 1,2/50 µs pulse) -
VX 81 0S
- Compact housing MiniLine
- All RF connections F-connector
- setting elements with rotary switch
- Flap-lid for easy handling
Down-Stream / DS
Frequency range downstream 85...1006 MHz Gain downstream 21 dB Frequency response ≤ ± 0,8 dB Output level ≥ 98 dBµV (CENELEC 42 Ch, flat, CTB/CSO ≥ 60 dB) IN-ATT (adjuster) 0...20 dB IN-EQ (adjuster) 0...20 dB Interstage-EQ (fix) 3 dB noise figure ≤ 7 dB Upstream (US)
US frequency range 5...65 MHz Gain upstream 16 dB Frequency response upstream ≤ ± 0,8 dB Output level 120 dBµV (KDG TS140 medium load; BER <1e 10-6) IN-ATT (adjuster) 0...20 dB noise figure ≤ 7 dB General data
HF-connections F Impedance 75 Ω Return loss ≥ 14 dB (> 40 MHz - 1,5 dB Oktave ≥ 10 dB) Lightning protection 1 kV (severity 1 / EN60728-3) EMC EN50083-2 Supply voltage 230 V (± 10%) Power consumption ≤ 4,5 W Ambient temperature -20...+55 °C Storage temperature -25...+75 °C Protection class IP20