VS 95

VS 93 B
-
VS 95
SAT-IF
Inputs SAT 2 pcs. (via filter) Frequency range SAT 950...2150 MHz Gain SAT 29...32 dB Attenuator SAT 20 dB Equalizer SAT 7 dB (switchable) Output level SAT 106 dB Noise figure SAT 6 dB terrestrial
Inputs TERR 2 pcs. (via filter) Frequency range TERR 47...862 MHz Gain TERR 23...29 dB Attenuator TERR 20 dB Equalizer TERR 6 dB (switchable) Output level TERR 117 dBµV Connectors
F-socket 4 pcs. General data
Operating voltage AC 230 V Power consumption 9 W LNB supply voltage 0 V LNB electrical power supply - A EMC Class A, EN 50083-2 Dimensions (width x height x depth) 177x122x40 mm Operating temperature range -10...+50 °C -
VS 93 B
splitt band amplifier to bring together terrestrial and 1 SAT frequency band on a trunk lineSAT-IF
Inputs SAT 1 pcs. Frequency range SAT 950...2400 MHz Gain SAT 27...35 dB Attenuator SAT 0...18 dB Equalizer SAT 8...16 dB (Jumper 0/8 dB + 8 dB fix) Output level SAT 115 dB Noise figure SAT 7 dB terrestrial
Inputs TERR 2 pcs. (1 active/1 passive) Frequency range TERR 5...862 MHz Gain TERR 13...18 dB Attenuator TERR 0...18 dB Equalizer TERR 5 dB (fix) Output level TERR 109 dBµV Output level 94 dBµV Insertion loss TERR 2.5 dB (passive way) Return channel frequency range 5...65 MHz Return path amplification -3 dB Connectors
F-socket 3 pcs. General data
Operating voltage AC 230 V (50/60 Hz) Power consumption 4 W LNB supply voltage 18 V LNB electrical power supply 0.3 A (short-circuit-proof) EMC
Dimensions (width x height x depth) 145x120x38 mm Operating temperature range -20...+50 °C